Colquhoun, D., Jonas, P., and Sakmann, B. (1992) Action of brief pulses of glutamate on AMPA/kainate receptors in patches
from different neurones of rat hippocampal slices. J. Physiol.
458, 261–287.
|
| |
Dilger, J. P. and Brett, R. S. (1990) Direct measurement of the concentration and time-dependent open probability of the nicotinic
acetylcholine recep tor channel. Biophys. J.
57, 723–731.
|
| |
Dudel, J., Franke, C., and Hatt, H. (1990) Rapid activation, desensitization, and resensitization of synaptic channels of
crayfish muscle after glutamate pulses. Biophys. J.
57, 533–545.
|
| |
| Dudel, J., Franke, C., and Hatt, H. (1992) High-speed application of drugs with a piezo drive, in Practical Elecrophysiological Methods (Kettenmann, H. and Grantyn, R., eds.), Wiley-Liss, New York, pp. 141–145.
|
| |
Dudel, J., Hallermann, S., and Heckmann, M. (2000) Quartz glass pipette puller operating with a regulated oxy-hydrogen burner.
Pflügers Arch.
441, 175–180.
|
| |
Eigen, M. (1968) New looks and outlooks on physical enzymology. Q. Rev. Biophys.
1, 3–33.
|
| |
Franke, C., Hatt, H., Parnas, H., and Dudel, J. (1991) Kinetic constants of the acetylcholine (ACh) receptor reaction deduced
from the rise in open probability after steps in ACh concentration. Biophys. J.
60, 1008–1016.
|
| |
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., and SigworthF. J. (1981) Improved patch-clamp techniques for high-resolution
current recording from cells and cell-free membrane patches. Pflügers Arch.
391, 85–100.
|
| |
Heckmann, M., Bufler, J., Franke, C., and Dudel, J. (1996) Kinetics of homomeric GluR6 glutamate receptor channels. Biophys. J.
71, 1743–1750.
|
| |
Heckmann, M. and Dudel, J. (1997) Desensitization and resensitization kinetics of glutamate receptor channels from Drosophila
larval muscle. Biophys. J.
72, 2160–2169.
|
| |
| Jonas, P. (1995) Fast application of agonists to isolated membrane patches, in Single-Channel Recording, 2nd ed. (Sakmann, B. and Neher, E., eds.), Plenum, New York, pp. 231–243.
|
| |
Sachs, F. (1999) Practical limits on the maximal speed of solution exchange for patch-clamp experiments. Biophys. J.
77, 682–690.
|
| |
Tour, O., Parnas, H., and Parnas, I. (1995) The double-ticker: an improved fast drug-application system reveals desensitization
of the glutamate channel from a closed state. Eur. J. Neurosci.
7, 2093–2100.
|
| |
von Beckerath, N., Adelsberger, H., Parzefall, F., Franke, C., and Dudel, J. (1995) GABAergic inhibition of crayfish deep
extensor abdominal muscle exhibits a steep dose-response relationship and a high degree of cooperativity. Pflügers Arch.
429, 781–788.
|
| |