| 1. |
Cuatrecasas P., Wilchek M., and Anfinsen C. B. (1968) Selective enzyme purification by affinity chromatography. Proc. Natl.
Acad. Sci. USA 61, 636–643.
|
| |
| 2. |
Lowe C. R. (1996) Adv. Mol. Cell Biol. 15B, 513–522.
|
| |
| 3. |
Kline T., ed. (1993) Handbook of Affinity Chromatography, Marcel Dekker New York.
|
| |
| 4. |
Wilchek M., Miron T., and Kohn J. (1984) Affinity chromatography. Methods Enzymol. 104, 3–56.
|
| |
| 5. |
Wilchek M. and Miron T. (1985) Appl. Biochem. Biotech. 11, 191–193.
|
| |
| 6. |
Wilchek M., Knudsen K.L. and Miron T. (1994) Improved method for preparing N-hydroxysuccinimide ester-containing polymers
for affinity chromatography. Bioconjug. Chem. 5, 491–492.
|
| |
| 7. |
Dunn B. M. and Chaiken I. M. (1974) Quantitative affinity chromatography. Determination of binding constants by elution with
competitive inhibitors. Proc. Natl. Acad. Sci. USA 71, 2382–2385.
|
| |
| 8. |
Swaisgood H. E., and Chaiken I. M. (1985) in Analytical Affinity Chromatography, (Chaiken I. M., ed.), CRC Press, Boca Raton,
FL, pp. 65–115.
|
| |
| 9. |
Fassina G. and Chaiken I. M. (1987) Analytical high-performance affinity chromatography. Adv. Chromatogr. 27, 248–297.
|
| |
| 10. |
Ohlson S., Bergstrom M., Pahlsson P., and Lundblad A. (1997) Use of monoclonal antibodies for weak affinity chromatography.
J. Chromatogr. A 758, 199–208.
<Occurrence Type="DOI"><Handle>10.1016/S0021-9673(96)00733-9</Handle></Occurrence>
|
| |
| 11. |
Johnsson B., Lofas S., and Lindquist G. (1991) Immobilization of proteins to a carboxymethyldextran-modified gold surface
for biospecific interaction analysis in surface plasmon resonance sensors. Anal. Biochem. 198, 268–277.
<Occurrence Type="DOI"><Handle>10.1016/0003-2697(91)90424-R</Handle></Occurrence>
|
| |
| 12. |
Jonsson U., Fagerstam L., Iversson B., Johnsson B., Karlsson R., Lundh K., Lofas S., Persson B., Roos H., and Ronnberg I.
(1991) Real-time biospecific interaction analysis using surface plasmon resonance and a sensor chip technology. Biotechniques
11, 620–627.
|
| |
| 13. |
Cush R., Cronin J. M., Stewart W. J., Maule C. H., Molloy J., and Goddard N. J. (1993) The resonant mirror: a novel optical
biosensor for direct sensing of biomolecular interactions. Part I. Principle of operation and associated instrumentation.
Biosensors Bioelectronics 8, 347–353.
<Occurrence Type="DOI"><Handle>10.1016/0956-5663(93)80073-X</Handle></Occurrence>
|
| |
| 14. |
Buckle P. E., Davies R. J., Kinning T., Yeung D., Edwards P. R., Pollard-Knight D., and Lowe C. R. (1993) The resonant mirror:
a novel optical biosensor for direct sensing of biomolecular interactions. Part II. Applications. Biosensors Bioelectronics
8, 355–363.
<Occurrence Type="DOI"><Handle>10.1016/0956-5663(93)80074-Y</Handle></Occurrence>
|
| |